The safety of elevators, which are the fundamental element of vertical transportation in buildings, is a critical issue both for the life safety of residents and in terms of legal sanctions. Under the Elevator Periodic Inspection Regulation in force, every elevator must be inspected at least once a year by accredited inspection bodies. At this point, conducting a professional elevator periodic inspection tracking process is an indispensable necessity to prevent potential accidents, avoid legal penalties, and ensure the elevator operates safely.

Apartment and housing estate managers, along with elevator maintenance companies, share a joint legal responsibility during inspection processes. Timely steps complying with the regulation must be taken, revisions required by the stickers issued after inspection must be completed, and maintenance records must be kept transparently. In this guide, we address the regulation details, the meanings of sticker colors, and modern tracking processes step by step.

Elevator Periodic Inspection Regulation and Legal Framework

Published by the Ministry of Industry and Technology, the Elevator Periodic Inspection Regulation aims to ensure that elevators in buildings with building permits operate throughout their service life after placement on the market without threatening life and property safety.

In accordance with the regulation, the basic rules are as follows:

  • Inspection Frequency: Periodic inspections of elevators must be conducted at least once a year.
  • Authorized Institution: Inspections are carried out by Type-A Inspection Bodies that have signed a protocol with the relevant administration (municipality or special provincial administration).
  • Division of Responsibility: Applying for the inspection and organizing the audit is the responsibility of the building manager; while having accompanying technical personnel present with the elevator during the audit and ensuring technical readiness is the responsibility of the authorized maintenance company.

It is a legal requirement to seal and decommission an elevator following inspections that are not conducted on time or result in a negative outcome. Therefore, it is of great importance not to delay maintenance and inspection dates.

Elevator Sticker Colors and Process Calendar

As a result of the periodic inspection, Type-A Inspection Body experts affix information stickers inside the cabin and on the landing doors according to the technical condition of the elevator. The colors of these stickers determine the safety status of the elevator and the actions required by the building management:

Sticker ColorSafety StatusDescriptionCorrection / Validity Period
Green StickerFlawlessIndicates that there is no risk to life and property safety.Valid for 1 year.
Blue StickerSlightly DefectiveIndicates minor deficiencies that do not directly threaten life and property safety.Deficiencies must be resolved within 12 months at the latest.
Yellow StickerDefectiveIndicates that the elevator is at an acceptable risk level, but defects exist.Defects must be resolved within 120 days at the latest.
Red StickerUnsafePoses a high risk to life and property safety. Its use must be stopped immediately.Defects must be resolved within 60 days at the latest.

By regulation, the use of an elevator that receives a red sticker must be stopped immediately and shut down by the building manager until it is sealed. If corrections are not made within the granted timeframe, the sealing process is executed by the authorized administration.

Checklist for Building Managers and Maintenance Companies

In order for periodic inspection processes to be completed smoothly, it is essential for both the building manager and the service provider company to follow specific stages completely.

Checklist for Building Managers

  1. Protocol Check: Has contact been made with the Type-A Inspection Body authorized by the relevant municipality?
  2. Authorized Maintenance Contract: Is there an active maintenance contract with an authorized maintenance company holding a TSE service qualification certificate for the elevator?
  3. Appointment and Coordination: Were the inspection body and the maintenance company coordinated for the same audit time?
  4. Revision Tracking: In case a red or yellow sticker was issued, was a revision proposal received from the maintenance company and work initiated within the legal timeframe?
  5. Follow-up Audit: After defects were resolved, was an application for a follow-up inspection submitted to the authorized body?

Checklist for Maintenance Companies

  1. Regular Monthly Maintenance: Was the last monthly periodic maintenance completed thoroughly prior to the annual inspection?
  2. Technical File and Registry Card: Are the elevator's registry card, maintenance logbook, and past inspection reports up to date?
  3. Inspection Accompaniment: Was the assigned technical personnel present with the necessary safety equipment during the audit?
  4. Reporting Defects: Were technical deficiencies in the inspection report quickly converted into a project plan and submitted in writing to the building management?
  5. Correction and Testing: Were the resolved defects tested in accordance with regulation standards?

How to Conduct Digital Elevator Periodic Inspection Tracking?

Tracking the periodic inspection schedules of dozens of elevators using traditional methods, paper contracts, or scattered notes can lead to operational errors. Missing sticker deadlines results in both administrative fines and the shutdown of elevators. The most effective way to prevent this chaos is to use modern elevator maintenance tracking software.

Digital systems make processes transparent by accelerating coordination between maintenance companies and building managements.

Maintenance and Breakdown Logging with QR Code Systems

Thanks to dynamic QR codes placed inside the elevator cabin or machine room, processes can be recorded instantly. With a modern elevator breakdown logging system:

  • Building residents or staff can instantly report an issue arising in the elevator by scanning the QR code with their phones.
  • When the field technician arrives at the address, they scan the QR code to initiate the work order and complete the maintenance steps.
  • Performed checks, replaced parts, and technical descriptions are recorded in the system; the elevator's past history is archived digitally.

Maintenance Contracts and Revision Tracking

The backbone of elevator operations is formed by elevator maintenance contract tracking. Via digital platforms:

  • Start, end, and renewal dates of contracts are tracked with automated reminders.
  • Revision parts and proposals created for elevators receiving yellow or red stickers are entered into the system.
  • Material procurement and work scheduling are initiated without delay upon approval from the manager.

Preventing Delays in Service Coordination

An advanced elevator tracking program enables viewing the workload of field teams instantly on a map or calendar. Which personnel is in which building, upcoming periodic inspection audits, and urgent breakdown calls are managed from a single dashboard. Thus, team dispatching speeds up, and disruptions such as lack of accompanying personnel on audit days are completely eliminated.

Exclusive for Elevator Companies: UrselaX Elevator Tracking Management

Offered under Ursela Software and Consulting, UrselaX Elevator Tracking Management is a comprehensive solution that digitalizes all business processes of elevator maintenance and repair companies. The system consolidates all steps on a single screen, from QR-based breakdown notifications to periodic maintenance calendars, green sticker audit processes, and field service coordination.

By managing your contracts, periodic audit periods, and technician work orders via the web panel or mobile app, you can minimize labor loss and establish transparent, reliable communication with building managements.

Frequently Asked Questions

How often should elevator periodic inspections be conducted?

In accordance with the Elevator Periodic Inspection Regulation in force, all registered elevators must be inspected at least once a year by a Type-A Inspection Body.

How much time is granted for an elevator that receives a red sticker?

Defects of unsafe elevators receiving a red sticker must be resolved within 60 days at the latest. During this period, keeping the elevator shut down for life safety is the responsibility of the building manager.

Who is responsible for having the elevator periodic inspection conducted?

Legally, the building manager or the board of flat owners is responsible for having the inspection conducted. The maintenance company, on the other hand, is obligated to provide technical accompaniment during the inspection.

What do companies gain from a digital elevator tracking program?

It prevents missing contract periods, monthly maintenance cycles, and legal audit days. It accelerates breakdown notifications, optimizes the routes of field staff, and archives the entire inspection history digitally in accordance with legal standards.


Explore UrselaX solutions to seamlessly manage your elevator maintenance operations, periodic inspection schedules, and breakdown notifications from a single hub. Contact us now or get a quote within minutes for detailed information about modules tailored to your business.